Grid Coupling Size Chart and Interchange: Lovejoy, Falk Steelflex, Dodge Grid-Lign, Browning Grid-Flex, Kop-Grid

Quick answer: Lovejoy grid couplings are interchangeable with the standard grid couplings from Falk (Steelflex), Dodge (Grid-Lign), Morse/Browning (Grid-Flex) and Kop-Flex (Kop-Grid). The size number is the same across brands: a Lovejoy 1090 matches a Falk 1090T10 (horizontal cover) or 1090T20 (vertical cover). The charts below give torque, speed, maximum bore, dimensions and misalignment limits for every size from 1020 to 1200, plus the part number cross-reference, from Lovejoy’s published catalogue. Size by torque first (application torque times service factor), then check the shaft bore.

Grid Coupling Performance Data, Sizes 1020 to 1200

SizeNominal torque (in-lbs)Nominal torque (Nm)Max RPM, horizontal coverMax RPM, vertical coverMax boreWeight, solid hubs (lbs)
1020460524,5006,0001.125 (28 mm)4.3
10301,3201494,5006,0001.375 (35 mm)5.7
10402,2002494,5006,0001.625 (42 mm)7.4
10503,8504354,5006,0001.875 (48 mm)12.0
10606,0506834,3506,0002.125 (54 mm)16.0
10708,8009944,1255,5002.500 (64 mm)23.0
108018,1502,0513,6004,7503.000 (76 mm)39.0
109033,0003,7283,6004,0003.500 (89 mm)56.0
110055,5506,2762,4003,2504.000 (102 mm)93.0
111082,5009,3212,2503,0004.500 (117 mm)120.0
1120121,00013,6712,0252,7005.000 (127 mm)180.0
1130176,00019,8841,8002,4006.000 (152 mm)270.0
1140253,00028,5841,6502,2007.250 (184 mm)394.0
1150352,00039,7691,500—8.000 (200 mm)523.0
1160495,00055,9251,350—9.000 (228 mm)720.0
1170660,00074,5671,225—10.000 (254 mm)1,022.5
1180915,200103,3991,100—11.000 (280 mm)1,341.7
11901,210,000136,7061,050—12.000 (305 mm)1,710.0
12001,650,000186,417900—13.000 (330 mm)2,331.0

Peak torque is typically twice the nominal value. Sizes 1020 to 1090 are bored clearance fit with two set screws at 90 degrees; sizes 1100 and larger are bored interference fit with no set screw. Vertical covers are not offered above size 1140. Source: Lovejoy Grid Coupling catalogue, page GD-10. TB Wood’s G-Flex ratings for sizes 1020 to 1140 match these figures; see our TB Wood’s G-Flex selection guide.

Grid Coupling Dimensions

SizeOverall length (OAL)Outside diameter, horizontal coverOutside diameter, vertical cover
10203.88 (98.5 mm)4.00 (101.6 mm)4.38 (111.3 mm)
10303.88 (98.5 mm)4.33 (110.0 mm)4.75 (120.7 mm)
10404.12 (104.7 mm)4.63 (117.6 mm)5.06 (128.5 mm)
10504.88 (123.8 mm)5.43 (138.0 mm)5.81 (147.6 mm)
10605.12 (130.0 mm)5.93 (150.5 mm)6.38 (162.1 mm)
10706.12 (155.5 mm)6.37 (161.8 mm)6.81 (173.0 mm)
10807.12 (180.8 mm)7.64 (194.0 mm)7.87 (199.9 mm)
10907.88 (200.0 mm)8.39 (213.0 mm)9.12 (231.7 mm)
11009.69 (246.1 mm)9.84 (250.0 mm)10.05 (255.3 mm)
111010.19 (258.7 mm)10.63 (270.0 mm)11.25 (285.8 mm)
112012.00 (304.8 mm)12.13 (308.0 mm)12.56 (319.0 mm)
113013.00 (330.2 mm)13.62 (346.0 mm)14.88 (378.0 mm)
114014.63 (371.6 mm)15.12 (384.0 mm)16.38 (416.1 mm)
115014.65 (372.1 mm)17.84 (453.1 mm)—
116015.85 (402.6 mm)19.74 (501.4 mm)—
117017.25 (437.1 mm)22.30 (566.4 mm)—
118019.05 (483.9 mm)24.80 (629.9 mm)—
119020.65 (524.5 mm)26.60 (675.6 mm)—
120022.25 (565.1 mm)29.80 (756.9 mm)—

Dimensions in inches (millimetres). Source: Lovejoy Grid Coupling catalogue, page GD-11.

Grid Coupling Interchange: Lovejoy, Falk, Browning, Dodge and Kop-Flex

Lovejoy sizeFalk Steelflex (horizontal)Morse/Browning Grid-Flex (horizontal)Dodge Grid-Lign (horizontal)Kop-Flex Kop-Grid (horizontal)Falk Steelflex (vertical)Morse/Browning Grid-Flex (vertical)Dodge Grid-Lign (vertical)Kop-Flex Kop-Grid (vertical)
10201020T10GF2020H1020T101020H1020T20GF2020V1020T201020V
10301030T10GF2030H1030T101030H1030T20GF2030V1030T201030V
10401040T10GF2040H1040T101040H1040T20GF2040V1040T201040V
10501050T10GF2050H1050T101050H1050T20GF2050V1050T201050V
10601060T10GF2060H1060T101060H1060T20GF2060V1060T201060V
10701070T10GF2070H1070T101070H1070T20GF2070V1070T201070V
10801080T10GF2080H1080T101080H1080T20GF2080V1080T201080V
10901090T10GF2090H1090T101090H1090T20GF2090V1090T201090V
11001100T10GF2100H1100T101100H1100T20GF2100V1100T201100V
11101110T10GF2110H1110T101110H1110T20GF2110V1110T201110V
11201120T10GF2120H1120T101120H1120T20GF2120V1120T201120V
11301130T10GF2130H1130T101130H1130T20GF2130V1130T201130V
11401140T10GF2140H1140T101140H1140T20GF2140V1140T201140V
11501150T10———————
11601160T10———————
11701170T10———————
11801180T10———————
11901190T10———————
12001200T10———————

Grid springs and covers follow the same size number, so a Lovejoy grid fits a Falk or TB Wood’s hub of the same size. Source: Lovejoy Grid Coupling catalogue, page GD-15 (industry standard interchange chart).

Grid Coupling Misalignment Limits

SizeParallel, installation (in)Parallel, operating (in)Angular, installation (in)Angular, operating (in)Nominal gap (in)
10200.0060.0120.0020.0090.118
10300.0060.0120.0030.0110.118
10400.0060.0120.0030.0130.118
10500.0080.0160.0040.0150.118
10600.0080.0160.0040.0180.118
10700.0080.0160.0050.0200.118
10800.0080.0160.0060.0240.118
10900.0080.0160.0070.0280.118
11000.0100.0200.0080.0320.177
11100.0100.0200.0090.0350.177
11200.0110.0220.0100.0400.236
11300.0110.0220.0120.0470.236
11400.0110.0220.0130.0530.236
11500.0120.0240.0150.0610.236
11600.0120.0240.0170.0700.236
11700.0120.0240.0200.0790.236
11800.0150.0300.0220.0890.236
11900.0150.0300.0240.0960.236
12000.0150.0300.0270.1070.236

Allowable angular misalignment is 1/16 degree at installation and 1/4 degree in operation. Source: Lovejoy Grid Coupling catalogue, page GD-14.

How to Select a Grid Coupling

  1. Calculate application torque. In-lbs = horsepower x 63,025 / RPM. In Nm = kW x 9,550 / RPM.
  2. Apply the service factor. Selection torque = application torque x service factor. Typical values: 1.0 for constant-torque loads such as centrifugal pumps and blowers, 1.5 for continuous duty with some torque variation, 2.0 for light shock, 2.5 for moderate shock, 3.0 for heavy shock such as crushers. For an application-specific list, see the TB Wood’s G-Flex service factor table.
  3. Pick the first size whose nominal torque is at or above the selection torque.
  4. Check the bore. Both shafts must fit within the maximum bore for that size. If not, move up a size.
  5. Check speed, gap and misalignment against the charts above. Use the vertical cover for higher speed.
  6. High peak loads or brakes: double the application torque before applying the service factor.

Worked example: a 60 HP motor at 1,760 RPM driving a rotary lobe compressor. Application torque is 60 x 63,025 / 1,760 = 2,149 in-lbs. With a service factor of 1.25, selection torque is 2,687 in-lbs. A size 1050 has enough torque, but the motor’s 2-1/8″ shaft exceeds its 1-7/8″ maximum bore, so the answer is a size 1060 (6,050 in-lbs, 2-1/8″ bore, 4,350 RPM limit).

Shop Grid Couplings and Parts

As an Amazon Associate we earn from qualifying purchases. We do not show prices; check the current price on Amazon.

Related: Grid couplings vs chain couplings: maintenance compared and Choosing the right grid coupling for heavy-duty applications.

FAQ

Is a Lovejoy grid coupling the same as a Falk Steelflex?
Lovejoy states its grid couplings are interchangeable with the standard Falk Steelflex series, with the same size numbers. A Lovejoy 1090 replaces a Falk 1090T10 (horizontal cover) or 1090T20 (vertical cover).

What do the T10 and T20 mean on a grid coupling?
T10 is the horizontally split cover and T20 is the vertically split cover, as shown in both Lovejoy’s interchange chart and TB Wood’s G-Flex catalogue. Dodge Grid-Lign uses the same codes.

Which is better, a horizontal or vertical cover?
Horizontal covers suit limited space and reversing duty. Vertical covers are the recommended choice for higher speed: up to 6,000 RPM on sizes 1020 to 1060, against 4,500 RPM for horizontal.

How much misalignment can a grid coupling take?
Installation limits are 1/16 degree angular and the parallel figures in the table above. In operation, up to 1/4 degree angular. For a size 1060 that is 0.008″ parallel at installation and 0.016″ in operation.

Do grid couplings dampen vibration?
Lovejoy says its tapered grid design can dampen vibration by as much as 30% and cushion shock loads by spreading impact energy along the grid spring.

Can I replace just the grid spring?
Yes. The split cover gives access to the spring so it can be replaced without moving the equipment, at a fraction of the cost of a new coupling.

Sources

  • Lovejoy, Inc., Grid Couplings catalogue section GD (pages GD-4 to GD-15): selection process, performance and dimensional data, misalignment capability and industry standard interchange chart.
  • TB Wood’s / Regal Rexnord, Belt Drives, Sheaves and Couplings, P-1686-TBW, section F4: G-Flex ratings and cover styles.

Brand names such as Falk Steelflex, Dodge Grid-Lign, Browning Grid-Flex and Kop-Flex Kop-Grid belong to their respective owners and are used only to identify compatible parts. The interchange chart is the manufacturer’s own; confirm hub dimensions and bore on the part in your hand before ordering.

Leave a Reply