Quick answer: Lovejoy grid couplings are interchangeable with the standard grid couplings from Falk (Steelflex), Dodge (Grid-Lign), Morse/Browning (Grid-Flex) and Kop-Flex (Kop-Grid). The size number is the same across brands: a Lovejoy 1090 matches a Falk 1090T10 (horizontal cover) or 1090T20 (vertical cover). The charts below give torque, speed, maximum bore, dimensions and misalignment limits for every size from 1020 to 1200, plus the part number cross-reference, from Lovejoy’s published catalogue. Size by torque first (application torque times service factor), then check the shaft bore.
Grid Coupling Performance Data, Sizes 1020 to 1200
Table of Contents
| Size | Nominal torque (in-lbs) | Nominal torque (Nm) | Max RPM, horizontal cover | Max RPM, vertical cover | Max bore | Weight, solid hubs (lbs) |
|---|---|---|---|---|---|---|
| 1020 | 460 | 52 | 4,500 | 6,000 | 1.125 (28 mm) | 4.3 |
| 1030 | 1,320 | 149 | 4,500 | 6,000 | 1.375 (35 mm) | 5.7 |
| 1040 | 2,200 | 249 | 4,500 | 6,000 | 1.625 (42 mm) | 7.4 |
| 1050 | 3,850 | 435 | 4,500 | 6,000 | 1.875 (48 mm) | 12.0 |
| 1060 | 6,050 | 683 | 4,350 | 6,000 | 2.125 (54 mm) | 16.0 |
| 1070 | 8,800 | 994 | 4,125 | 5,500 | 2.500 (64 mm) | 23.0 |
| 1080 | 18,150 | 2,051 | 3,600 | 4,750 | 3.000 (76 mm) | 39.0 |
| 1090 | 33,000 | 3,728 | 3,600 | 4,000 | 3.500 (89 mm) | 56.0 |
| 1100 | 55,550 | 6,276 | 2,400 | 3,250 | 4.000 (102 mm) | 93.0 |
| 1110 | 82,500 | 9,321 | 2,250 | 3,000 | 4.500 (117 mm) | 120.0 |
| 1120 | 121,000 | 13,671 | 2,025 | 2,700 | 5.000 (127 mm) | 180.0 |
| 1130 | 176,000 | 19,884 | 1,800 | 2,400 | 6.000 (152 mm) | 270.0 |
| 1140 | 253,000 | 28,584 | 1,650 | 2,200 | 7.250 (184 mm) | 394.0 |
| 1150 | 352,000 | 39,769 | 1,500 | — | 8.000 (200 mm) | 523.0 |
| 1160 | 495,000 | 55,925 | 1,350 | — | 9.000 (228 mm) | 720.0 |
| 1170 | 660,000 | 74,567 | 1,225 | — | 10.000 (254 mm) | 1,022.5 |
| 1180 | 915,200 | 103,399 | 1,100 | — | 11.000 (280 mm) | 1,341.7 |
| 1190 | 1,210,000 | 136,706 | 1,050 | — | 12.000 (305 mm) | 1,710.0 |
| 1200 | 1,650,000 | 186,417 | 900 | — | 13.000 (330 mm) | 2,331.0 |
Peak torque is typically twice the nominal value. Sizes 1020 to 1090 are bored clearance fit with two set screws at 90 degrees; sizes 1100 and larger are bored interference fit with no set screw. Vertical covers are not offered above size 1140. Source: Lovejoy Grid Coupling catalogue, page GD-10. TB Wood’s G-Flex ratings for sizes 1020 to 1140 match these figures; see our TB Wood’s G-Flex selection guide.
Grid Coupling Dimensions
| Size | Overall length (OAL) | Outside diameter, horizontal cover | Outside diameter, vertical cover |
|---|---|---|---|
| 1020 | 3.88 (98.5 mm) | 4.00 (101.6 mm) | 4.38 (111.3 mm) |
| 1030 | 3.88 (98.5 mm) | 4.33 (110.0 mm) | 4.75 (120.7 mm) |
| 1040 | 4.12 (104.7 mm) | 4.63 (117.6 mm) | 5.06 (128.5 mm) |
| 1050 | 4.88 (123.8 mm) | 5.43 (138.0 mm) | 5.81 (147.6 mm) |
| 1060 | 5.12 (130.0 mm) | 5.93 (150.5 mm) | 6.38 (162.1 mm) |
| 1070 | 6.12 (155.5 mm) | 6.37 (161.8 mm) | 6.81 (173.0 mm) |
| 1080 | 7.12 (180.8 mm) | 7.64 (194.0 mm) | 7.87 (199.9 mm) |
| 1090 | 7.88 (200.0 mm) | 8.39 (213.0 mm) | 9.12 (231.7 mm) |
| 1100 | 9.69 (246.1 mm) | 9.84 (250.0 mm) | 10.05 (255.3 mm) |
| 1110 | 10.19 (258.7 mm) | 10.63 (270.0 mm) | 11.25 (285.8 mm) |
| 1120 | 12.00 (304.8 mm) | 12.13 (308.0 mm) | 12.56 (319.0 mm) |
| 1130 | 13.00 (330.2 mm) | 13.62 (346.0 mm) | 14.88 (378.0 mm) |
| 1140 | 14.63 (371.6 mm) | 15.12 (384.0 mm) | 16.38 (416.1 mm) |
| 1150 | 14.65 (372.1 mm) | 17.84 (453.1 mm) | — |
| 1160 | 15.85 (402.6 mm) | 19.74 (501.4 mm) | — |
| 1170 | 17.25 (437.1 mm) | 22.30 (566.4 mm) | — |
| 1180 | 19.05 (483.9 mm) | 24.80 (629.9 mm) | — |
| 1190 | 20.65 (524.5 mm) | 26.60 (675.6 mm) | — |
| 1200 | 22.25 (565.1 mm) | 29.80 (756.9 mm) | — |
Dimensions in inches (millimetres). Source: Lovejoy Grid Coupling catalogue, page GD-11.
Grid Coupling Interchange: Lovejoy, Falk, Browning, Dodge and Kop-Flex
| Lovejoy size | Falk Steelflex (horizontal) | Morse/Browning Grid-Flex (horizontal) | Dodge Grid-Lign (horizontal) | Kop-Flex Kop-Grid (horizontal) | Falk Steelflex (vertical) | Morse/Browning Grid-Flex (vertical) | Dodge Grid-Lign (vertical) | Kop-Flex Kop-Grid (vertical) |
|---|---|---|---|---|---|---|---|---|
| 1020 | 1020T10 | GF2020H | 1020T10 | 1020H | 1020T20 | GF2020V | 1020T20 | 1020V |
| 1030 | 1030T10 | GF2030H | 1030T10 | 1030H | 1030T20 | GF2030V | 1030T20 | 1030V |
| 1040 | 1040T10 | GF2040H | 1040T10 | 1040H | 1040T20 | GF2040V | 1040T20 | 1040V |
| 1050 | 1050T10 | GF2050H | 1050T10 | 1050H | 1050T20 | GF2050V | 1050T20 | 1050V |
| 1060 | 1060T10 | GF2060H | 1060T10 | 1060H | 1060T20 | GF2060V | 1060T20 | 1060V |
| 1070 | 1070T10 | GF2070H | 1070T10 | 1070H | 1070T20 | GF2070V | 1070T20 | 1070V |
| 1080 | 1080T10 | GF2080H | 1080T10 | 1080H | 1080T20 | GF2080V | 1080T20 | 1080V |
| 1090 | 1090T10 | GF2090H | 1090T10 | 1090H | 1090T20 | GF2090V | 1090T20 | 1090V |
| 1100 | 1100T10 | GF2100H | 1100T10 | 1100H | 1100T20 | GF2100V | 1100T20 | 1100V |
| 1110 | 1110T10 | GF2110H | 1110T10 | 1110H | 1110T20 | GF2110V | 1110T20 | 1110V |
| 1120 | 1120T10 | GF2120H | 1120T10 | 1120H | 1120T20 | GF2120V | 1120T20 | 1120V |
| 1130 | 1130T10 | GF2130H | 1130T10 | 1130H | 1130T20 | GF2130V | 1130T20 | 1130V |
| 1140 | 1140T10 | GF2140H | 1140T10 | 1140H | 1140T20 | GF2140V | 1140T20 | 1140V |
| 1150 | 1150T10 | — | — | — | — | — | — | — |
| 1160 | 1160T10 | — | — | — | — | — | — | — |
| 1170 | 1170T10 | — | — | — | — | — | — | — |
| 1180 | 1180T10 | — | — | — | — | — | — | — |
| 1190 | 1190T10 | — | — | — | — | — | — | — |
| 1200 | 1200T10 | — | — | — | — | — | — | — |
Grid springs and covers follow the same size number, so a Lovejoy grid fits a Falk or TB Wood’s hub of the same size. Source: Lovejoy Grid Coupling catalogue, page GD-15 (industry standard interchange chart).
Grid Coupling Misalignment Limits
| Size | Parallel, installation (in) | Parallel, operating (in) | Angular, installation (in) | Angular, operating (in) | Nominal gap (in) |
|---|---|---|---|---|---|
| 1020 | 0.006 | 0.012 | 0.002 | 0.009 | 0.118 |
| 1030 | 0.006 | 0.012 | 0.003 | 0.011 | 0.118 |
| 1040 | 0.006 | 0.012 | 0.003 | 0.013 | 0.118 |
| 1050 | 0.008 | 0.016 | 0.004 | 0.015 | 0.118 |
| 1060 | 0.008 | 0.016 | 0.004 | 0.018 | 0.118 |
| 1070 | 0.008 | 0.016 | 0.005 | 0.020 | 0.118 |
| 1080 | 0.008 | 0.016 | 0.006 | 0.024 | 0.118 |
| 1090 | 0.008 | 0.016 | 0.007 | 0.028 | 0.118 |
| 1100 | 0.010 | 0.020 | 0.008 | 0.032 | 0.177 |
| 1110 | 0.010 | 0.020 | 0.009 | 0.035 | 0.177 |
| 1120 | 0.011 | 0.022 | 0.010 | 0.040 | 0.236 |
| 1130 | 0.011 | 0.022 | 0.012 | 0.047 | 0.236 |
| 1140 | 0.011 | 0.022 | 0.013 | 0.053 | 0.236 |
| 1150 | 0.012 | 0.024 | 0.015 | 0.061 | 0.236 |
| 1160 | 0.012 | 0.024 | 0.017 | 0.070 | 0.236 |
| 1170 | 0.012 | 0.024 | 0.020 | 0.079 | 0.236 |
| 1180 | 0.015 | 0.030 | 0.022 | 0.089 | 0.236 |
| 1190 | 0.015 | 0.030 | 0.024 | 0.096 | 0.236 |
| 1200 | 0.015 | 0.030 | 0.027 | 0.107 | 0.236 |
Allowable angular misalignment is 1/16 degree at installation and 1/4 degree in operation. Source: Lovejoy Grid Coupling catalogue, page GD-14.
How to Select a Grid Coupling
- Calculate application torque. In-lbs = horsepower x 63,025 / RPM. In Nm = kW x 9,550 / RPM.
- Apply the service factor. Selection torque = application torque x service factor. Typical values: 1.0 for constant-torque loads such as centrifugal pumps and blowers, 1.5 for continuous duty with some torque variation, 2.0 for light shock, 2.5 for moderate shock, 3.0 for heavy shock such as crushers. For an application-specific list, see the TB Wood’s G-Flex service factor table.
- Pick the first size whose nominal torque is at or above the selection torque.
- Check the bore. Both shafts must fit within the maximum bore for that size. If not, move up a size.
- Check speed, gap and misalignment against the charts above. Use the vertical cover for higher speed.
- High peak loads or brakes: double the application torque before applying the service factor.
Worked example: a 60 HP motor at 1,760 RPM driving a rotary lobe compressor. Application torque is 60 x 63,025 / 1,760 = 2,149 in-lbs. With a service factor of 1.25, selection torque is 2,687 in-lbs. A size 1050 has enough torque, but the motor’s 2-1/8″ shaft exceeds its 1-7/8″ maximum bore, so the answer is a size 1060 (6,050 in-lbs, 2-1/8″ bore, 4,350 RPM limit).
Shop Grid Couplings and Parts
- Lovejoy 1060 grid coupling hub, 2″ bore
- Lovejoy 1050 grid coupling hub, 1″ bore
- Lovejoy 1020 horizontal cover set and grid assembly
- Falk Steelflex 1050T coupling with grid
- Falk 1040T20 cover and grid assembly
- TB Wood’s 1020T20 grid vertical cover kit
- Kop-Flex 1040 grid coupling
- SKF 1060TGGRID grid coupling
As an Amazon Associate we earn from qualifying purchases. We do not show prices; check the current price on Amazon.
Related: Grid couplings vs chain couplings: maintenance compared and Choosing the right grid coupling for heavy-duty applications.
FAQ
Is a Lovejoy grid coupling the same as a Falk Steelflex?
Lovejoy states its grid couplings are interchangeable with the standard Falk Steelflex series, with the same size numbers. A Lovejoy 1090 replaces a Falk 1090T10 (horizontal cover) or 1090T20 (vertical cover).
What do the T10 and T20 mean on a grid coupling?
T10 is the horizontally split cover and T20 is the vertically split cover, as shown in both Lovejoy’s interchange chart and TB Wood’s G-Flex catalogue. Dodge Grid-Lign uses the same codes.
Which is better, a horizontal or vertical cover?
Horizontal covers suit limited space and reversing duty. Vertical covers are the recommended choice for higher speed: up to 6,000 RPM on sizes 1020 to 1060, against 4,500 RPM for horizontal.
How much misalignment can a grid coupling take?
Installation limits are 1/16 degree angular and the parallel figures in the table above. In operation, up to 1/4 degree angular. For a size 1060 that is 0.008″ parallel at installation and 0.016″ in operation.
Do grid couplings dampen vibration?
Lovejoy says its tapered grid design can dampen vibration by as much as 30% and cushion shock loads by spreading impact energy along the grid spring.
Can I replace just the grid spring?
Yes. The split cover gives access to the spring so it can be replaced without moving the equipment, at a fraction of the cost of a new coupling.
Sources
- Lovejoy, Inc., Grid Couplings catalogue section GD (pages GD-4 to GD-15): selection process, performance and dimensional data, misalignment capability and industry standard interchange chart.
- TB Wood’s / Regal Rexnord, Belt Drives, Sheaves and Couplings, P-1686-TBW, section F4: G-Flex ratings and cover styles.
Brand names such as Falk Steelflex, Dodge Grid-Lign, Browning Grid-Flex and Kop-Flex Kop-Grid belong to their respective owners and are used only to identify compatible parts. The interchange chart is the manufacturer’s own; confirm hub dimensions and bore on the part in your hand before ordering.